AIM-M200 Insulation Monitoring Device

AIM-M200 Insulation Monitoring Device

short description:

● Accurate Insulation Resistance monitoring
● Load&Temperature monitoring for Insulation Transformer
● Prompt Alarm with Relay Output and LED Indicator once Insulation
Fault or IT System Devices Disconnection happened
● Smart HMI for convenient Parameter&Alarm Setting and Self-test
● Support Insulation Fault Location Function
● RS485&CAN bus Communication
● IEC 60364-7-710:2002;IEC62020-1:2020; EMC

Product Detail

Product Tags

Features

AIM-M200-7
Accurate Insulation Resistance monitoring

● Isolation Measuring Range:10~999Ω

● Relative Tolerance:0~±10%

● Display Method:value&percentage display

Insulation measurement LCD display
Load&Temperature monitoring for Insulation Transformer

● Thermistor: PT100

● Temperature Measuring Range: -50℃~+200℃

● Residual Current Measuring Range: 2.1~50A

● Accuracy: 5%

 

AMI-M200 monitor load and temperature of insulation transformer

Prompt Alarm with Relay Output and LED Indicator once Insulation Fault&IT System Devices Disconnection happened

● Response Time:<2s

● LED Indicator:Insulation Fault&Overload&Over-temperature Alarm; Connected Device status (on-off)

● Alarm Relay Output: 2 relay output (non-programmable)

 

LCD display and relay output  terminal of AIM-M200 Hospital Insulation Monitoring Device

 

Smart HMI for convenient Parameters&Alarm Setting and Self-test

● Alarm Threshold Value Setting

● Response Time setting

● Self Test

 

Keypads HMI illustration

 

Parameters

Parameters/Model
AIM-M10 AIM-M100 AIM-M200 
Auxiliary power Voltage AC220V(±10%) DC24V(±25%)
Frequency 50/60Hz
Power consumption <5VA < 8VA <3VA
Insulation monitoring Insulation resistance measurement range 10~999kΩ
Accuracy 0~±10%
Alarm value range 50~999kΩ
Response time <2s
Measuring voltage <12V
Measuring current <50uA
Current Monitoring Measurement value 2.1~50A
Alarm value range 5~50A
Accuracy 5%
Display method Value display Percentage display Value and percentage display
Temperature Monitoring Sensor PT100
Measuring range -50~+200℃
Alarm value range 0~+200℃
Power output 24VDC 2W None
Alarm Output Output 1 relay 2 relay(programmable) 2 relay (not programmable)
Contact Capacity AC 250V/3A DC 30V/3A
Communications 1 RS485 , Modbus-RTU 2 RS485 , Modbus-RTU 1 RS485, Modbus-RTU
1 CAN, custom protocol
Environment Operating temperature -10~+50℃
Storage temperature -20~+70℃
Relative humidity 5%-95%,No condensation
Altitude ≤2500m
Rated impulse voltage / pollution degree 4KV/3
EMC & EMR IEC61326-2-4

Quotation

Note: Price below Only for Reference, Contact us for your Best Quotation !!!

Shape Type Function FOB Shanghai(USB) Module Price(USD)
  AIM-M10 Monitoring the insulation resistance of IT system;Relay output 1776 1 Double communications+1302 Fault alarm output+64

3 Temperature monitoring+130

4 Load monitoring+130

5 Centralized monitoring software+482

6.Disconnection monitonng+130

7 SOE+322

8 Self-test* 160

  AIM-M100 2310
  AIM-M200 2900
  ACLP10-24 DC24V linear power supply module. 44  

 

  HDR-60-24 DC24V power supply module. 66
  AIL150-4 Locate up to 4 fault branches with ASG150. 896
  AIL 150-8 Locate up to 8 fault branches with ASG150. 1150
  ASG150 Generate location signal when insulation fault occurs,locate fault branches with AIL150;

L1/L2 disconnection alarm.

560
  AID10 Alarm when fault occurred: Matching with AIM-M10. 88  

 

  AID120 Display the insulation resistance and load rate in real time;Alarm with LED display when fault occurred;

Matching with AIM-M100.

132
  AID150 Remote monitoring up to16 sets of insulation monitors by RS485;Remote setting and self-test,

20 fault records;

132
  AID200 Remote monitoring up to16 sets of insulation monitors by CAN bus;Remote setting and self-test;

20 fault records;

Matching with AIM-M200.

132
  AIM-R100 12 channels residual current;1 relay output;

20 fault records;

128*32 bits LCD;

RS485(Modbus-RTU);

Response range:6mA-1A

1296
  AKH-0.66P26 Protective current transformer (used with AIM-M series);Max current: 50A;

Current ratio: 2000:1.

22
AKH-0 66/L-20 Residual current transformer (used with AIM-R100);

Max current: 100A;

Current ratio: 2000:1.

22

Wiring Instruction

AIM-M200-10

Typical Application