head_banner

Power Sensor

  • AC Active&Reactive Power Transducer BD-4PQI (3-phase 4-wire)

    AC Active&Reactive Power Transducer BD-4PQI (3-phase 4-wire)

    ● Measurement: 3-phase AC Active&Reactive Power (Range: -866~+866W)

     Accuracy: Class 0.5

    ● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 4-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Active&Reactive Power Transducer BD-3PQI (3-phase 3-wire)

    AC Active&Reactive Power Transducer BD-3PQI (3-phase 3-wire)

    ● Measurement: 3-phase AC Active&Reactive Power (Range: -866~+866W)

     Accuracy: Class 0.5

    ● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 3-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Active Power Transducer BD-4P (3-phase 4-wire)

    AC Active Power Transducer BD-4P (3-phase 4-wire)

    ● Measurement: 3-phase AC Active Power (Range: 0~+866W)

     Accuracy: Class 0.5

    ● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 4-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • Solid Core Current Transformer AKH-0.66I 80I

    Solid Core Current Transformer AKH-0.66I 80I

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.2/Class 0.5/Class 1.0

     Primary Current Input: 150~3000A AC

    ● Application: On Busbar or Cable

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail

     Loop Count of Cable: 1

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • Solid Core Current Transformer AKH-0.66I 60I

    Solid Core Current Transformer AKH-0.66I 60I

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.2/Class 0.5/Class 1.0

     Primary Current Input: 150~2500A AC

    ● Application: On Busbar or Cable

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail

     Loop Count of Cable: 1

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • Solid Core Current Transformer AKH-0.66I 40I

    Solid Core Current Transformer AKH-0.66I 40I

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.5/Class 1.0

     Primary Current Input: 10~1000A AC

    ● Application: On Busbar or Cable

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail

     Loop Count of Cable: 1~10 Loops

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • Solid Core Current Transformer AKH-0.66I 30I

    Solid Core Current Transformer AKH-0.66I 30I

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.2/Class 0.5/Class 1.0

     Primary Current Input: 15~600A AC

    ● Application: On Busbar or Cable

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail

     Loop Count of Cable: 1~5 Loops

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • AC Current Transducer BA05-AII

    AC Current Transducer BA05-AII

    ● Input: 0~(0.5~10)A AC

    ● Output: 4~20mA/0~20mA DC

     Power Supply: 12V/24V DC

    ● Perforation Hole Size: φ5mm

     Applicaiton: Paired with PLC for Industrial Automation

    ● Accuracy: Class 0.5

    ● Response Time: ≤350ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE; TüV

  • AC Residual Current Transducer BA50L-AII

    AC Residual Current Transducer BA50L-AII

    ● Input: 0~(0.1~1)A AC

    ● Output: 4~20mAV/0~20mA DC

     Power Supply: 12V/24V DC

    ● Perforation Hole Size: φ50mm

     Applicaiton: Paired with PLC for Industrial Automation

    ● Accuracy: Class 0.5

    ● Response Time: ≤350ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE; TüV

  • AC Current Transducer BA50-AIV

    AC Current Transducer BA50-AIV

    ● Input: 0~(60~600)A AC

    ● Output: 1~5V/0~5V DC

     Power Supply: 12V/24V DC

    ● Perforation Hole Size: φ50mm

     Applicaiton: Paired with PLC for Industrial Automation

    ● Accuracy: Class 0.5

    ● Response Time: ≤350ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE; TüV

  • AC Current Transducer BA20-AII

    AC Current Transducer BA20-AII

    ● Input: 0~(40~200)A AC

    ● Output: 4~20mA/0~20mA DC

     Power Supply: 12V/24V DC

    ● Perforation Hole Size: φ20mm

     Applicaiton: Paired with PLC for Industrial Automation

    ● Accuracy: Class 0.5

    ● Response Time: ≤350ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE; TüV

  • AC Current Transducer BA10-AII

    AC Current Transducer BA10-AII

    ● Input: 0~(8~50)A AC

    ● Output: 4~20mA/0~20mA DC

     Power Supply: 12V/24V DC

    ● Perforation Hole Size: φ10mm

     Applicaiton: Paired with PLC for Industrial Automation

    ● Accuracy: Class 0.5

    ● Response Time: ≤350ms

    ● Installation: 35mm DIN Rail/Screw fixed