AIM-M200 Insulation Monitoring Device
Features
Accurate Insulation Resistance monitoring
● Isolation Measuring Range:10~999Ω ● Relative Tolerance:0~±10% ● Display Method:value&percentage display |
Load&Temperature monitoring for Insulation Transformer
● Thermistor: PT100 ● Temperature Measuring Range: -50℃~+200℃ ● Residual Current Measuring Range: 2.1~50A ● Accuracy: 5% |
Prompt Alarm with Relay Output and LED Indicator once Insulation Fault&IT System Devices Disconnection happened
● Response Time:<2s ● LED Indicator:Insulation Fault&Overload&Over-temperature Alarm; Connected Device status (on-off) ● Alarm Relay Output: 2 relay output (non-programmable) |
|
Smart HMI for convenient Parameters&Alarm Setting and Self-test
● Alarm Threshold Value Setting ● Response Time setting ● Self Test |
|
Parameters
Parameters/Model
|
AIM-M10 | AIM-M100 | AIM-M200 | |
Auxiliary power | Voltage | AC220V(±10%) | DC24V(±25%) | |
Frequency | 50/60Hz | — | ||
Power consumption | <5VA | < 8VA | <3VA | |
Insulation monitoring | Insulation resistance measurement range | 10~999kΩ | ||
Accuracy | 0~±10% | |||
Alarm value range | 50~999kΩ | |||
Response time | <2s | |||
Measuring voltage | <12V | |||
Measuring current | <50uA | |||
Current Monitoring | Measurement value | 2.1~50A | ||
Alarm value range | 5~50A | |||
Accuracy | 5% | |||
Display method | Value display | Percentage display | Value and percentage display | |
Temperature Monitoring | Sensor | PT100 | ||
Measuring range | -50~+200℃ | |||
Alarm value range | 0~+200℃ | |||
Power output | 24VDC | 2W | None | |
Alarm Output | Output | 1 relay | 2 relay(programmable) | 2 relay (not programmable) |
Contact Capacity | AC 250V/3A DC 30V/3A | |||
Communications | 1 RS485 , Modbus-RTU | 2 RS485 , Modbus-RTU | 1 RS485, Modbus-RTU | |
1 CAN, custom protocol | ||||
Environment | Operating temperature | -10~+50℃ | ||
Storage temperature | -20~+70℃ | |||
Relative humidity | 5%-95%,No condensation | |||
Altitude | ≤2500m | |||
Rated impulse voltage / pollution degree | 4KV/3 | |||
EMC & EMR | IEC61326-2-4 |
Quotation
Note: Price below Only for Reference, Contact us for your Best Quotation !!!
Shape | Type | Function | FOB Shanghai(USB) | Module Price(USD) |
AIM-M10 | Monitoring the insulation resistance of IT system;Relay output | 1776 | 1 Double communications+1302 Fault alarm output+64
3 Temperature monitoring+130 4 Load monitoring+130 5 Centralized monitoring software+482 6.Disconnection monitonng+130 7 SOE+322 8 Self-test* 160 |
|
AIM-M100 | 2310 | |||
AIM-M200 | 2900 | |||
ACLP10-24 | DC24V linear power supply module. | 44 |
|
|
HDR-60-24 | DC24V power supply module. | 66 | ||
AIL150-4 | Locate up to 4 fault branches with ASG150. | 896 | ||
AIL 150-8 | Locate up to 8 fault branches with ASG150. | 1150 | ||
ASG150 | Generate location signal when insulation fault occurs,locate fault branches with AIL150;
L1/L2 disconnection alarm. |
560 | ||
AID10 | Alarm when fault occurred: Matching with AIM-M10. | 88 |
|
|
AID120 | Display the insulation resistance and load rate in real time;Alarm with LED display when fault occurred;
Matching with AIM-M100. |
132 | ||
AID150 | Remote monitoring up to16 sets of insulation monitors by RS485;Remote setting and self-test,
20 fault records; |
132 | ||
AID200 | Remote monitoring up to16 sets of insulation monitors by CAN bus;Remote setting and self-test;
20 fault records; Matching with AIM-M200. |
132 | ||
AIM-R100 | 12 channels residual current;1 relay output;
20 fault records; 128*32 bits LCD; RS485(Modbus-RTU); Response range:6mA-1A |
1296 | ||
AKH-0.66P26 | Protective current transformer (used with AIM-M series);Max current: 50A;
Current ratio: 2000:1. |
22 | ||
AKH-0 66/L-20 | Residual current transformer (used with AIM-R100);
Max current: 100A; Current ratio: 2000:1. |
22 |