-
ATC600 Wireless Temperature Data Transceiver
● Receive Temperature Data: From up to 240 ATE Series Temperature Sensors
● Communication Methods: GFSK (with Temperature Sensors)
● Communication Distance: 1000m in open Area & 100m in Building
● Extra RS485 Communication: MODBUS-RTU
● DO Function: 2 Relay Output
● Dimension: 90*38*90mm (L*W*H)
● Installation: 35mm DIN Rail
● Power Supply: AC/DC 85~265V or DC 12-48V
-
ASCB1-63-C32 2P Smart Circuit Breaker
● Over Current / Power / Temp. Protection;
● Over / Under Voltage Protection;
● Short Circuit Protection;● Remote turn on/off
● Leakage Current Protection. -
Acrel Insulation Power Distribution Cabinet
● Suitable for Power Distribution System in Group 2 Medical Location
● Using Q235A Cold Rolled Steel Plate
● Cooling Fan
● Various installation types
● IP31 Protection Level
● IEC60364-7-710:2016; IEC 61439-2:2011
-
AIM-M200 Insulation Monitoring Device
● Accurate Insulation Resistance monitoring● Load&Temperature monitoring for Insulation Transformer● Prompt Alarm with Relay Output and LED Indicator once InsulationFault or IT System Devices Disconnection happened● Smart HMI for convenient Parameter&Alarm Setting and Self-test● Support Insulation Fault Location Function● RS485&CAN bus Communication● IEC 60364-7-710:2002;IEC62020-1:2020; EMC -
ATP Series Remote Temperature Data Display Touchscreen
● Display Temperature Data: From up to 240 ATE Wireless Temperature Sensors● Communication: 1-channel Ethernet & 2-channel RS485 (MODBUS-RTU)● Touch Screen Size: 7 Inch & 10 Inch● Cut-out Dimension: 215*152mm & 261*180mm● Power Supply: 24V DC (±10%) -
AGF-AE-D Bidirectional Reflux Monitoring Meter (2-phase,3-wire with UL certificate)
● Measurement: Active Powr, Reactive Power, Current, Voltage and etc
● Wiring: 1-phase 3-wire Connection
● Current Rating: 100A or 200A AC (paired with external CTs)
● Communication: RS485 (MODBUS-RTU)
● Application: Using in distributed Solar PV and Anti-reflux Inverters
● Dimension: 54.1*87.8*52mm (H*W*D)
● Installation: 35mm DIN Rail
● Standard&Certificate: UL1741;TUV
-
ADL100-ET/CT Single-phase DIN Rail Energy Meter connect with current transformer
● Reference Voltage: AC 220V
● Input Current: 10(60)A
● Small Compact Size
● Diverse Electricity Parameters Measurement
● Multi-rate/Flexible Tariff
● HMI for Parameters Setting
● DIN Rail Installation
● RS485 (MODBUS-RTU)
● IEC62053-21:2003; IEC62053-22:2003; CE; EAC
-
DTSD1352-C Three-phase Multi-function DIN Rail Energy Meter for solar inverter zero export
● Measurement: 3-phase kWh (0.5S), Active Power, Reactive Power, Current, Voltage, Harmonic and etc
● Voltage Rating: 3×220/380V, 3×57.7/100V (3P4W); 3x380V, 3x100V (3P3W)
● Current Rating: 3×10(80)A; 3×1(6)A
● Frequency: 45~65Hz
● Commnunication: RS485 (MODBUS-RTU) and Infrared
● Multi-rate: Spike, Peak, Valley and Flat kWh
● Extra Function: Cable Temperature Measurement and DO/DI
● Display: LCD (8 digits)
● Dimension: 127*88*70mm (L*W*H)
● Wiring: 3-phase 4wire; 3-phase 3-wire
● Installation: 35mm DIN Rail
● Standard&Certificate: IEC; CE; EAC
-
Acrel ABAT series Lead acid Battery String Monitoring System for BMS
●BMS for lead acid battery
●Modbus communication
●string battery monitor for 2V, 6V, 12V batteries
-
ADW310 IoT 1-phase Wireless Smart Energy Meter
● Wireless Comms.: 4G, WiFi (MQTT, MODBUS-TCP)
● Wired Comms.: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 20(100)A AC (via paired CT)
● Measurement: 1-phase Active&Reactive Energy, Active&Reactive Power, Current, Voltage, Frequncy, Power Factor, Apparent Power
● I/O Function: 1-way DI & 1-way DO
● Temperature: 2-way Cable Temperature Measurement
● Pulse Output: Active Pulse Output
-
ANAPF Active Power Filter
● 380V±15%,50Hz±2%
● Full response time ≤ 5ms
● 30A, 50A, 75A,100A or 150A
● RS485(Modbus-RTU)or Ethernet(Modbus-TCP)
● Frozen data
● 2-51st Harmonics
-
AM2SE Protection Relay
● A complete set of protection, related to the application;
● 4 current input, 3 voltage input, 8DI, 5DO;
● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V, DC48V, DC24V;
● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;
● More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
● Powerful graphic programmable Logic.