DC Multi-function Energy Meter PZ72L-DE
● Measurement: 1-circuit DC kWh, kVarh, U, I, P and etc
● Accuracy: 0.5%
● Rated Voltage: 1000V DC
● Rated Current: 10A DC (direct connect); 0/4~20mA DC (via Hall Sensor); 75mV (via Shunts)
● Power Supply: 85~265V AC/DC; 20~60V DC
● Communication: RS485 (MODBUS-RTU)
● ±12V Power Ouput: Paired with Hall Sensor
● DI/DO Function: 2/4-channel DI&2-channel DO
● Multi-rate/tariff: 4 Tariff Rates and etc
● Standard&Certificate: CE Certificates
-
AGF-MxxT DC Multi-Circuits Monitoring Device for PV Combiner Box
● Measurement: DC Current of up to 24 Circuits (with Hall Sensors); Voltage of Busbar
● Communication: RS485 (MODBUS-RTU)
● Application: Paired with PV Combiner Box for DC Multi-circuits Monitoring
● Temperature Monitoring: Inner Temperature of PV Combiner Box
● DI Function: 3-channel Digital Input
● Display: LCD Display
● Installation: 35mm DIN Rail (Main Body); Perforation (Cable)
● Power Supply: 1000V DC or 1500V DC
● Standard&Certificate: CE;LVD;EMC
-
Three-phase AC Multi-function Panel Energy Meter AMC96L-E4KC
● Measurement: 3-phase AC kWh, kVarh, I, U, kW, kVar, Hz, cosφ and etc
● Accuracy: 1% (kWh); 0.5% (Active Power)
● Rated Voltage: 400V or 660V AC L-L (direct connect); 100V AC L-L (via PTs)
● Rated Current: 5A AC or 1A AC (via CTs)
● Power Supply: 85~265V AC/DC; 24V or 48V DC
● Communication: RS485 (MODBUS-RTU)
● SOE Funciton: Event&Demand&Extremum Record
● Harmonic Measurement: 2~31st and total Harmonic
● Analog Output: 4~20mA DC or 1~5V DC
● DI/DO Function: 2/4-channel DI&2-channel DO
● Standard&Certificate: CE Certificates
-
Multi-circuits Prepaid Energy Meter ADF400L (1-phase&3-phase)
● Application: Prepaid&Postpaid (See about Acrel Prepaid Solution)
● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed
● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc
● Rated Voltage: 3×220/380V (50Hz)
● Rated Current: 80A AC (direct connection); 3×1(6)A AC (via CTs)
● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared
● Communication (Expanded): 4G; WiFi; LoRa
● Remote Control: DO&DI
● Installtion: 35mm DIN Rail
● Power Supply: 3*220/380V or 220V AC
● Standard&Certificate: CE
-
APM8xx Series AC Multi-function Smart Meter
● Measurement: 3-phase kWh, kVarh, kW, I, U, Hz, Cosφ, Current&Voltage Unbalance, 2~63rd Harmonic, Real-time&Max Demand, Zero-sequence Current, 4-quadrant Energy and etc
● Current Rating: -/5A AC; -/1A AC (According to CTs)
● Voltage Rating: 100V, 110V, 400V, 690V AC
● Frequency: 45~65Hz
● Accuracy: Up to 0.2S (Optional)
● Communication (Main Body): RS485 (MODBUS-RTU)
● Communication (Expanded): PROFIBUS-DP; Ethernet; Secondary RS485
● Extra Function: 8DI/2DO; 8AI/4AO; SOE (with standard 4GB SD Card); Multi-rate
● Display: LCD Display
● Dimension: 96*96*90mm (L*W*H)
● Installation: Panel Embedded (Cut-out –92*92mm)
● Power Supply: 85~265V AC/DC; 115~415V AC/DC
● Standard&Certificate: CE
-
AMC16Z-ZA Dual-circuit Data Center Energy Meter
● Monitoring: Dual Independent AC Incoming Circuits 3-phase (For Data Center)
● Measurement: Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc
● Power Quality: 2nd~63rd&Total Harmonic, Current&Voltage Unbalance and etc
● Communicaiton: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 1(6)A AC (via CTs)
● Standard&Certificate: CE; IEC; LVD
-
AITR Series Medical Insulation Transformer
● Insulation Transformer for Hospital IT Power System
● Double Insulation Treatment
● Electrostatic Shielding Layer
● PT100 Temperature Sensor Embedded in the Winding
● CE; IEC 61558-1:2009; IEC 61558-2-15:2011; IEC60364-7-710:2016
-
ADL3000-ECT Three-phase Multi-function DIN Rail Energy Meter (with External CTs)
● Measurement: 3-phase kWh (0.5S), Active Power, Reactive Power, Current, Voltage, Harmonic and etc
● Voltage Rating: 3×220/380V, 3×57.7/100V (3P4W); 3x380V, 3x100V (3P3W)
● Current Rating: 3×10(100)A; 3×1(6)A
● Frequency: 45~65Hz
● Commnunication: RS485 (MODBUS-RTU) and Infrared
● Multi-rate: Spike, Peak, Valley and Flat kWh
● Extra Function: Cable Temperature Measurement and DO/DI
● Display: LCD (8 digits)
● Dimension: 127*88*70mm (L*W*H)
● Wiring: 3-phase 4wire; 3-phase 3-wire
● Installation: 35mm DIN Rail
● Standard&Certificate: IEC; CE; EAC
-
ADL3000-E Three-phase Multi-function DIN Rail Energy Meter
● Measurement: 3-phase kWh (0.5S), Active Power, Reactive Power, Current, Voltage, Harmonic and etc
● Voltage Rating: 3×220/380V, 3×57.7/100V (3P4W); 3x380V, 3x100V (3P3W)
● Current Rating: 3×10(80)A; 3×1(6)A
● Frequency: 45~65Hz
● Commnunication: RS485 (MODBUS-RTU) and Infrared
● Multi-rate: Spike, Peak, Valley and Flat kWh
● Extra Function: Cable Temperature Measurement and DO/DI
● Display: LCD (8 digits)
● Dimension: 127*88*70mm (L*W*H)
● Wiring: 3-phase 4wire; 3-phase 3-wire
● Installation: 35mm DIN Rail
● Standard&Certificate: IEC; CE; EAC
-
ADL100-ET Single-phase DIN Rail Energy Meter
● Reference Voltage: AC 220V
● Input Current: 10(60)A
● Small Compact Size
● Diverse Electricity Parameters Measurement
● Multi-rate/Flexible Tariff
● HMI for Parameters Setting
● DIN Rail Installation
● RS485 (MODBUS-RTU)
● IEC62053-21:2003; IEC62053-22:2003; CE; EAC
-
ACR10R-DxxTEx Bidirectional Three-phase Reflux Monitoring Energy Meter
● Measurement: 3-phase Active Power, Reactive Power, Current, Voltage and etc
● Current Rating: up to 300A (with CTs); up to 20000A (with Rogowski Coil)
● Communication: RS485 (MODBUS-RTU)
● Application: Using in distributed Solar PV and Anti-reflux Inverter
● Display: LCD Display
● Dimension: 54*64*84mm (L*W*H)
● Installation: 35mm DIN Rail
● Power Supply: 85~265V AC or 100~350V DC
● Standard&Certificate: CE
-
ACR10R-DxxT Bidirectional Single-phase Reflux Monitoring Energy Meter
● Measurement: 1-phase Active Power, Reactive Power, Current, Voltage and etc
● Current Rating: up to 300A (paired with external CTs)
● Communication: RS485 (MODBUS-RTU)
● Application: Using in distributed Solar PV and Anti-reflux Inverter
● Display: LCD Dispaly
● Dimension: 54*74*85mm (L*W*H)
● Installation: 35mm DIN Rail
● Power Supply: 85~265V AC or 100~350V DC
● Standard&Certificate: CE