  • Split Core Current Sensors For Busbar AKH-0.66-K

    Split Core Current Sensors For Busbar AKH-0.66-K

    ● Split core current transformer

    ● Easy to install without power off

    ● Suitable for electricity renovation project

  • Split Core Current Transformer AKH-0.66K-φ16

    Split Core Current Transformer AKH-0.66K-φ16

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.5

     Primary Current Input: 20~100A  Output: 10-40mA

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Clamp-on (installed on Cable)

     Loop Count: 1 Loop

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • Split Core Current Transformer AKH-0.66K-φ24

    Split Core Current Transformer AKH-0.66K-φ24

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.5

     Primary Current Input: 150~300A AC

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Clamp-on (installed on Cable)

     Loop Count: 1 Loop

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • Split Core Current Transformer AKH-0.66K-φ36

    Split Core Current Transformer AKH-0.66K-φ36

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.5

     Primary Current Input: 300~600A AC

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Clamp-on (installed on Cable)

     Loop Count: 1 Loop

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • DC Voltage Transducer BD-DV (1-phase 2-wire)

    DC Voltage Transducer BD-DV (1-phase 2-wire)

    ● Measurement: 1-phase DC Voltage

     Accuracy: Class 0.5

    ● Input: 0~75mV/0~10V/0~300V DC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V DC

    ● Wiring: 1-phase 2-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • DC Current Transducer BD-DI (1-phase 2-wire)

    DC Current Transducer BD-DI (1-phase 2-wire)

    ● Measurement: 1-phase DC Current

     Accuracy: Class 0.5

    ● Input: 4~20mA/0~20mA DC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V DC

    ● Wiring: 1-phase 2-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Voltage Transducer BD-4V3 (3-phase 4-wire)

    AC Voltage Transducer BD-4V3 (3-phase 4-wire)

    ● Measurement: 3-phase AC Voltage

     Accuracy: Class 0.5

    ● Input: 0~120V/0~300V/0~500V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 4-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Voltage Transducer BD-3V3 (3-phase 3-wire)

    AC Voltage Transducer BD-3V3 (3-phase 3-wire)

    ● Measurement: 3-phase AC Voltage

     Accuracy: Class 0.5

    ● Input: 0~120V/0~300V/0~500V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 3-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Reactive Power Transducer BD-4Q (3-phase 4-wire)

    AC Reactive Power Transducer BD-4Q (3-phase 4-wire)

    ● Measurement: 3-phase AC Reactive Power (Range: -866~0W)

     Accuracy: Class 0.5

    ● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 4-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Reactive Power Transducer BD-3Q (3-phase 3-wire)

    AC Reactive Power Transducer BD-3Q (3-phase 3-wire)

    ● Measurement: 3-phase AC Reactive Power (Range: -866~0W)

     Accuracy: Class 0.5

    ● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 3-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Power Factor Transducer BD-PF (3-phase 4-wire)

    AC Power Factor Transducer BD-PF (3-phase 4-wire)

    ● Measurement: 3-phase AC Power Factor (Range: 0~1)

     Accuracy: Class 0.5

    ● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 4-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Multi-function Transducer BD-4E (3-phase 4-wire)

    AC Multi-function Transducer BD-4E (3-phase 4-wire)

    ● Measurement: 3-phase Current, Voltage, Active&Reactive Power, Power Factor, Frequency, kWh, kVarh and etc

     Accuracy: Class 0.5

    ● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 4-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE