AC Frequency Transducer BD-F (3-phase 4-wire)
● Measurement: 3-phase AC Frequency (Range: 45~50~55Hz)
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 4-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
-
AC Multi-function Transducer BD-3E (3-phase 3-wire)
● Measurement: 3-phase Current, Voltage, Active&Reactive Power, Power Factor, Frequency, kWh, kVarh and etc
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 3-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
-
AC Current Transducer BD-3I3 (3-phase 3-wire)
● Measurement: 3-phase AC Current
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 3-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
-
AC Active&Reactive Power Transducer BD-4PQI (3-phase 4-wire)
● Measurement: 3-phase AC Active&Reactive Power (Range: -866~+866W)
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 4-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
-
AC Active&Reactive Power Transducer BD-3PQI (3-phase 3-wire)
● Measurement: 3-phase AC Active&Reactive Power (Range: -866~+866W)
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 3-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
-
AC Active Power Transducer BD-4P (3-phase 4-wire)
● Measurement: 3-phase AC Active Power (Range: 0~+866W)
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 4-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
-
Solid Core Current Transformer AKH-0.66I 80I
● Measurement: Alternating Current (AC)
● Accuracy: Class 0.2/Class 0.5/Class 1.0
● Primary Current Input: 150~3000A AC
● Application: On Busbar or Cable
● Rated Voltage: 660V AC
● Rated Frequency: 50~60Hz
● Installtion: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail
● Loop Count of Cable: 1
● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE
-
Solid Core Current Transformer AKH-0.66I 60I
● Measurement: Alternating Current (AC)
● Accuracy: Class 0.2/Class 0.5/Class 1.0
● Primary Current Input: 150~2500A AC
● Application: On Busbar or Cable
● Rated Voltage: 660V AC
● Rated Frequency: 50~60Hz
● Installtion: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail
● Loop Count of Cable: 1
● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE
-
Solid Core Current Transformer AKH-0.66I 40I
● Measurement: Alternating Current (AC)
● Accuracy: Class 0.5/Class 1.0
● Primary Current Input: 10~1000A AC
● Application: On Busbar or Cable
● Rated Voltage: 660V AC
● Rated Frequency: 50~60Hz
● Installtion: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail
● Loop Count of Cable: 1~10 Loops
● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE
-
Solid Core Current Transformer AKH-0.66I 30I
● Measurement: Alternating Current (AC)
● Accuracy: Class 0.2/Class 0.5/Class 1.0
● Primary Current Input: 15~600A AC
● Application: On Busbar or Cable
● Rated Voltage: 660V AC
● Rated Frequency: 50~60Hz
● Installtion: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail
● Loop Count of Cable: 1~5 Loops
● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE
-
AC Current Transducer BA05-AII
● Input: 0~(0.5~10)A AC
● Output: 4~20mA/0~20mA DC
● Power Supply: 12V/24V DC
● Perforation Hole Size: φ5mm
● Applicaiton: Paired with PLC for Industrial Automation
● Accuracy: Class 0.5
● Response Time: ≤350ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE; TüV
-
AC Residual Current Transducer BA50L-AII
● Input: 0~(0.1~1)A AC
● Output: 4~20mAV/0~20mA DC
● Power Supply: 12V/24V DC
● Perforation Hole Size: φ50mm
● Applicaiton: Paired with PLC for Industrial Automation
● Accuracy: Class 0.5
● Response Time: ≤350ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE; TüV