head_banner

Power Sensor

  • Acrel ABAT series Lead acid Battery String Monitoring System for BMS

    Acrel ABAT series Lead acid Battery String Monitoring System for BMS

    ●BMS for lead acid battery

    ●Modbus communication

    ●string battery monitor for 2V, 6V, 12V batteries

  • Split Core Current Transformer AKH-0.66K-φ10

    Split Core Current Transformer AKH-0.66K-φ10

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.5

     Primary Current Input: 5~60A Output: 1.25-20mA

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Clamp-on (installed on Cable)

     Loop Count: 1 Loop

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • AHKC-EKA Open-loop Hall Effect Transducer (Split-core)

    AHKC-EKA Open-loop Hall Effect Transducer (Split-core)

    ● Rated Input: 0~±500A DC or 0~500A AC

    ● Rated Output: 0~±5/±4Vdc

     Aperture: φ20mm

    ● Power Supply: ±12~±15Vdc

    ● Accuracy: Class 1.0

    ● Response Time: ≤5us

    ● Installation: Clamp on (Split-core) measuring cable and screw fixed on panel

    ● Standard&Certificate: CE; IEC; LVD

  • AC Active Power Transducer BD-3P (3-phase 3-wire)

    AC Active Power Transducer BD-3P (3-phase 3-wire)

    ● Measurement: 3-phase AC Active Power (Range: 0~+866W)

     Accuracy: Class 0.5

    ● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC

    ● Wiring: 3-phase 3-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Current Transducer BD-AI (1-phase 2-wire)

    AC Current Transducer BD-AI (1-phase 2-wire)

    ● Measurement: 1-phase AC Current

     Accuracy: Class 0.5

    ● Input: 0~1A AC/0~5A AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485(MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V DC

    ● Wiring: 1-phase 2-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • AC Voltage Transducer BD-AV (1-phase 2-wire)

    AC Voltage Transducer BD-AV (1-phase 2-wire)

    ● Measurement: 1-phase AC Voltage

     Accuracy: Class 0.5

    ● Input: 0~120V/0~300V/0~500V AC

    ● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485(MODBUS-RTU)

     Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V DC

    ● Wiring: 1-phase 2-wire

     Applicaiton: Paired with PLC for Industrial Automation; Used for Metering

    ● Response Time: ≤400ms

    ● Installation: 35mm DIN Rail/Screw fixed

    ● Standard&Certificate: CE

  • BR Rogowski Coil Transducer

    BR Rogowski Coil Transducer

    Measurement

    - Rogowski coil and RMS measurement

    - Super-current measurement, direct measurement up to 30000A

    - Overload: 1.2 times of rated value

     

    Application

    - Industrial automation

    - Metallurgical and electroplating

  • AHKC-EKC Open-loop Hall Effect Transducer (Split-core)

    AHKC-EKC Open-loop Hall Effect Transducer (Split-core)

    ● Rated Input: 0~±1500A DC or 0~1500A AC

    ● Rated Output: 0~±5/±4Vdc

     Aperture: φ55mm

    ● Power Supply: ±12~±15Vdc

    ● Accuracy: Class 1.0

    ● Response Time: ≤5us

    ● Installation: Clamp on (Split-core) measuring cable and screw fixed on panel

    ● Standard&Certificate: CE; IEC; LVD

  • AHKC-EKB Open-loop Hall Effect Transducer (Split-core)

    AHKC-EKB Open-loop Hall Effect Transducer (Split-core)

    ● Rated Input: 0~±1000A DC or 0~1000A AC

    ● Rated Output: 0~±5/±4Vdc

     Aperture: φ40mm

    ● Power Supply: ±12~±15Vdc

    ● Accuracy: Class 1.0

    ● Response Time: ≤5us

    ● Installation: Clamp on (Split-core) measuring cable and screw fixed on panel

    ● Standard&Certificate: CE; IEC; LVD

  • Split Core Current Sensors For Busbar AKH-0.66-K

    Split Core Current Sensors For Busbar AKH-0.66-K

    ● Split core current transformer

    ● Easy to install without power off

    ● Suitable for electricity renovation project

  • Split Core Current Transformer AKH-0.66K-φ16

    Split Core Current Transformer AKH-0.66K-φ16

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.5

     Primary Current Input: 20~100A  Output: 10-40mA

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Clamp-on (installed on Cable)

     Loop Count: 1 Loop

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

  • Split Core Current Transformer AKH-0.66K-φ24

    Split Core Current Transformer AKH-0.66K-φ24

    ● Measurement: Alternating Current (AC)

    ● Accuracy: Class 0.5

     Primary Current Input: 150~300A AC

    ● Rated Voltage: 660V AC

    ● Rated Frequency: 50~60Hz

    ● Installtion: Clamp-on (installed on Cable)

     Loop Count: 1 Loop

    ● Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE

1234 Next > >> Page 1 / 4